Home > Informix Error > Informix Error 952

Informix Error 952

The password that is specified for the server computer in your ~/.netrc file or in the USER clause of a CONNECT statement is incorrect. Yikes! Read 26 Feb 12 - BernieSpan.com - Better results, lower cost for a broad set of new IBM clients and partners... Cause This is a known IBM AIX product defect. have a peek at this web-site

It works before the reinstalation with the same software. This article explains one scenario and a possible solution for that problem. The following error message appears in the online.log file: listener-thread: err = -952: oserr = 0: errstr = informix: User (informix)'s password is not correct for the database server. the password is greater than 8 characters the database server was not started as user informix or root If you are using password shadowing, the following are also possible causes of a fantastic read

The error shown in the Informix instance message log file will be similar to Password Validation for user [user1] failed! Read 2 Aug 12 - channelbiz - Oninit Group launches Pay Per Pulse cloud-based service... Diagnosing the problem If the user can log on at the operating system Informix is running on, the user credentials are stored in an LDAP server and Informix is not configured Read Previous news items End of Support Dates IDS 11.10 - 30 Sep 2012 Subscribe to notifications Home Member Area About IIUG Help Resources IIUG Insider IIUG Hotspots Informix Links

Read 1 Feb 12 - developerWorks - 100 Tech Tips, #47: Log-in to Fix Central... and the password is 6 charaters long. Re: a way to get error 952 when wrong password IDS (views: 624)PING TANG -- Friday, 13 March 2009, at 11:48 a.m. How long is the password ?

Read 13 Jan 12 - MC Press online - Informix Dynamic Server Entices New Users with Free Production Edition ... Good luck. Find in the shadow file (etc/security/passwd for AIX, /etc/shadow for RedHat, Solaris, HP11i) the entry corresponding to the user. http://www-01.ibm.com/support/docview.wss?uid=swg21682007 Reply With Quote 07-25-02,17:29 #7 rnealejr View Profile View Forum Posts Registered User Join Date Feb 2002 Posts 2,232 The 952 error can be caused by many issues - one of

Read 06 Sep 13 - IBM data magazine - Mission Accomplished - Miami, Florida will be the backdrop for the 2014 IIUG Informix Conference... I intend to change the version of informix we are on to allow shadow passwords again. Copy the encrypted password from step 3. Hi everyone, im having a problems with the code error 952 when the users inputs password wrong because informix shows me error 951.

  1. Thank You -- Julio Lozano Julio Lozano Guest October 20th,11:25 AM #2 Re: ERROR -952 reboot ? -- Tsutomu Ogiwara from Tokyo Japan.
  2. Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility Register Help Remember Me?
  3. and I have never connected to this server before via ODBC.

Read 19 May 10 - The New Blog Times - Misurare il consumo energetico: DEHEMS è pronto... http://www-01.ibm.com/support/docview.wss?uid=swg21650838 Read 12 Oct 10 - Database Trends and Applications - Informix 11.7: The Beginning of the Next Decade of IBM Informix... The same user can use a telnet and isql without any problem. Read 10 February 2010 - The Wall Street Journal - International Business Machines is expanding an initiative to win over students and professors on its products.

Reply With Quote 07-23-02,19:59 #4 rnealejr View Profile View Forum Posts Registered User Join Date Feb 2002 Posts 2,232 I believe this is a known bug with uc5 and the fix Check This Out By MSFT in forum ASP Replies: 0 Last Post: September 25th, 03:23 AM An error occurred while try to load the string resources (GetModuleHandle failed with error -2147023888) By Marco Gerlach Read 9 Mar 11 - DBTA - Database Administration and the Goal of Diminishing Downtime... Read 6 Feb 12 - PRLOG - Informix port delivers unlimited database scalability for popular SaaS application ...

The supported LPAs and their attributes are defined in the /etc/security/pwdalg.cfg system configuration file. Register Forum Archives Databases Informix ERROR -952 ERROR -952 - Informix I have reinstaled an INFORMIX IDS 7.30 on a IBM AIX 4.2. Results 1 to 11 of 11 Thread: -952 Error Tweet Thread Tools Show Printable Version Subscribe to this Thread… Search Thread Advanced Search Display Linear Mode Switch to Hybrid Mode Source Note - using PAM is the preferred method for handling this situation, so use this as a temporary work-around only while taking steps to properly remedy the issue.

The server is a linux box based on redhat 6.2. However, if you start it as user 'root', problem does not occur. Advertisement dBforums Brief Subscribe to dBforums Brief to receive special offers from dBforums partners and sponsors Top Helpers healdem - 59 mark.b - 55 Pat Phelan - 54 ranman256 - 23

Resolving the problem Take one of the following actions where applicable: Ensure the permissions of the oninit binary are rwsr-sr--, owner is root and group is informix Try running the instance

Read 24 Feb 12 - developerWorks - Informix Warehouse Accelerator: Continuous Acceleration during Data Refresh... This password hash will then be compared with the hash of the password that the user provided, and when the comparison is successful the user will be authenticated. Read 28 Aug 12 - techCLOUD9 - Splunk kicks up a SaaS Storm... Read 28 May 12 - Bloor - David Norfolk on the recent Informix benchmark "pretty impressive results"...

I am getting the following error. "[Informix][ODBC Driver][Informix] user "%S" password is not correct for the database server." - on the ODBC side. "Daemon err=-952: users password is not correct for The defect identifier is IY80055: SECURITY ROUTINES MISHANDLES IF PASSWD FILE IS RENAMED ON THE FLY This problem is due to a problem with AIX's passwd mechanism, where the password is Read 20 Jul 10 - IBM Announcements - IBM Informix Choice Edition V11.50 helps deploy low-cost scalable and reliable solutions for Apple Macintosh and Microsoft Windows... http://clockworklaw.com/informix-error/informix-error-507.php Messages In This Thread a way to get error 952 when wrong password IDS FC9 (views: 960)LYNKZ MIKE -- Friday, 13 March 2009, at 10:28 a.m.

Watson Product Search Search None of the above, continue with my search Error -952 occurs on IBM Informix Dynamic Server using AIX 5.3 after changing password through a remote server AIX; All rights reserved. Read 10 Aug 12 - businessCLOUD9 - Is this the other half of Cloud monitoring?... Document information More support for: Informix Servers Software version: 11.5, 11.7, 12.1 Operating system(s): AIX Reference #: 1664590 Modified date: 13 February 2014 Site availability Site assistance Contact and feedback Need

Symptom A user with credentials stored in an LDAP server can log on at the operating system on which an Informix instance is running, but receives an error -952 when trying Unix and Informix use the same Unix facility to validate passwords. I got the same problem with informix 7.24 UC5. Watson Product Search Search None of the above, continue with my search Connections to database server are not allowed when Informix started with user informix on AIX platform.

Environment The following products and operating systems are affected: Product Name Product Version(s) Hardware Vendor Operating System IBM Informix Dynamic Server 7.31 9.40 10.00 IBM AIX 5.3 Resolving the problem Contact Reply With Quote 07-25-02,09:34 #6 pklucas View Profile View Forum Posts Registered User Join Date Jul 2002 Location Parkersburg, WV Posts 5 Thank'sfor the info. Symptom Assumptions: 100% confidence that the account/password combination is correct The OS is properly configured to authenticate Kerberos/AD user accounts The user account is a remote Kerberos/AD account AIX OS A Watson Product Search Search None of the above, continue with my search -951 and -952 errors when connecting as user informix on AIX LPA; AIX; PAM; password; encryption Technote (troubleshooting) Problem(Abstract)

This value does not match the crypt hash value of the passed-in password. Lester Knutsen (IBM Champion) writes about database back up safety using "archecker"... When we had IDS 10.00.FC4, when the user inputs wrong password he got error 952 which wrong password, now we are using 10.00.FC9 when users inputs wrong password he gets 951