Home > Error Code > Infinity Spa Error Code Sl

Infinity Spa Error Code Sl

Contents

The Spa or Hot Tub Panel Displays: SN, Sn1, Sn2 Sn3, HL, E1, E3, Prh, HtS, Blinking Lights Again these can be caused by a flow issue. AnswerTrevor, Here is a rundown on some of those error codes you are getting: The 'Sl' stands for Sleep mode, which the spa will not heat in this mode. After about 45 Seconds, Check for Error Messages on the Topside Panel Display. The Spa or Hot Tub Panel Displays: SL This indicates the system is in sleep mode and can be changed by pressing the up temp. have a peek at this web-site

Back to Top LF or LOW FLOW Message There is a Verified "Low Flow" (LF) Condition in the Heater.The "HFL", "HL", or "HTR FLOW LOW" Fault has occurred 5 times in OHH Overheat. Contact qualified service technician. Back to Top rtC or RTC FAILURE Message The "Real Time Clock" (rtC) Cannot be Read.At Power-Up, the System Board Real Time Clock could Not be Read.

Hot Tub Error Codes

The temp sensor is the larger of the two silver bullets. This indicates a Possible Problem with The System Board. One sensor has detected 118º F. Select "Message Other than rtC or RTC FAILURE" Below.

Priming Mode lasts 4 minutes, but you can exit it earlier by pressing any Temp button. **Note: The term "circ pump" refers to a low-speed-only pump that is used for heating FLO2 Closed or shorted flow switch on system startup Dream Maker Spa Side Error Codes OH Overheat Protection (Heater is deactivated, pumps low speed is activated). Back to Top PHH or PH IS HIGH LOWER PH Message At the pH Sensor, the "pH Level is High" (PHH).With a pH Sensor Installed in the System, the pH Level Marquis Spa Error Codes Heater is deactivated.F2 = 4 hours daily filtrationF4 = 8 hours daily filtrationF6 = 12 hours daily filtrationFC = continuous filtration EasyPak Control Systems for Spas or Hot Tubs: C =

Turn OFF the Power to the System and Turn it back ON again to put System into Priming Mode.2. See M7 Sensors here. drops.HL = High limit switch tripped. http://www.justanswer.com/pool-and-spa/5moys-cannot-hot-tub-sl-sleep-mode-shut-off.html I wanted to thank you for your time explaining what I needed, as I wasn't 100% sure if what I was ordering was correct.

Once there the spa should heat up to the set temperature. How To Fix Flo Error Hot Tub Too Many Closed Jets.6. Check water level in spa. Low speed pump and heater will activate until spa reaches 65ºF.OH = High temperature condition, has reached 110ºF.

  • Submitted: 5 years ago.
  • I received my hottub the other day, from costco.
  • Depending on where the temp sensor is mounted; usually in the wall of the spa in a sensor mount, you could have a flow issue.
  • Spa has shut down.
  • System will restart when temp.
  • drops.
  • One sensor has detected 110°F.
  • Check for clogged filter.FL2 = Pressure switch problem.
  • How do I get it to work properly or is there a problem within the spa?

Balboa Hot Tub Error Codes

OH, OHH, OHS, OHt, HL, HiLi, Sn2, Sn3, tS, Ht, Blinking Lights Temperature Sensor Failure. I received my hottub the other day, from costco. Hot Tub Error Codes Heat Related Pump Not Primed.9. Infinity Spa Control Panel Balboa Control Manufacturer Scroll past Common Error Codes for: What common codes actually mean and what you can check prior to scheduling service Common Spa or Hot Tub Error

Could indicate a flow problem. http://clockworklaw.com/error-code/international-error-code-7.php The low speed pump or circ pump will operate continuously until the temperature rises above 45° F. On the subsequent power-ups, the GFCI test is skipped because the proper flag has been set in the software.Note: The GFCI Test Feature should only be Enabled in the United States Press "Mode" Button to Clear Message. Vita Spa Error Codes

See picture below for reference FINAL NOTE: Balboa M7 systems have the Temperature Sensor as well as the Hi Limit sensor installed in the heater assembly, one at each end. Pump may also be deactivated). I would appreciate any help out there!! http://clockworklaw.com/error-code/infinity-error-codes-cable-box.php FL1 = Water flow problem, inhibited or pressure switch malfunction.

I have pushed all the different buttons and have the heat set to 104 but it won't heat that high, also I see there are modes like F2, F4, F6, F8 Infinity Spas COOL = Spa water is more than 20° F cooler than the temperature set point.FLO* = Flow Switch (heater is deactivated. This could indicate poor flow or air bubbles in the heater.

HOT = Circuit Board temperature has exceeded acceptable limit.

COL = Cool condition. ICE Freeze condition. 55ºF detected. Check for Water Level, Flow Restrictions, Closed Valves, Air Bubbles, and Pump Prime, or contact your Dealer or Service Organization.Check for All of the following Conditions:1. Great Lakes Hot Tub Error Codes Back to Top CrC or CHKSUM FAIL Message "Cyclic Redundancy Code" (CrC) Checksum Error.A "Cyclic Redundancy Code" (CrC) is a type of checksum algorithm that takes a string of data bytes

Some Spa Brands or Models may have this Message Enabled, and the Interval between these Messages will be whatever the Spa Manufacturer has selected. ICE2 Freeze protection. Spa unusable. have a peek here The spa topside panel messages include common diagnostic messages, operational messages, and various other messages such as reminders.

DO NOT remove the protective covers from any electrical enclosure, or attempt to service any related electrical device, unless you are a qualified electrician or service professional. Spa has shut down. The hottub seems real nice but it came with nothing, missing the manual, filter cartridge, filter lid, head cushions, etc. If the GFCI does not trip for some reason, the gFI fault will appear and the HOt flag will be set.If the spa is subsequently powered down and then powered up

button then pressing the mode or light button depending on the system. To Schedule Service Click Here: Contact Us Home | Service area | Contact Us | Testimonials | Blog Chris Questioner's RatingRating(1-10)Knowledgeability = 10Clarity of Response = 10Politeness = 10CommentNo Comment Add to this AnswerAsk a Question Related ArticlesBMW 325ic Slowly OverheatsDodge Shadow Codes 22 And 37Dodge Shadow Codes 22 You can skip Priming Mode if you're restarting the spa for some other reason (without the water having been drained since the last time the spa functioned properly). The "SF" Safety Fault Error Message indicates that the Vacuum Switch has closed, indicating that there has been a Suction Problem or a Possible Entrapment Situation Avoided.2.

Heater disabled but the spa is operational. Disclaimer: Although we hope this information will be useful, error codes are subject to change without notice. FL = Flow. The most common valve; the tee handle valve, will show that the handle is up, but in many cases the gate is still half closed, make sure that it is open

If Not, Continue to Next Step.Spas with Pump Suction Blockage Switch:1. Get a Professional Answer Via email, text message, or notification as you wait on our site.Ask follow up questions if you need to. 100% Satisfaction Guarantee Rate the answer you receive.